You are here

Plant & Machinery – Equipments for Beta Napthol & Bon Acid

No Description Quantity Specification
1 Diesel fired baby boiler 1 -
2 Cooling tower 1 -
3 Air compressor – LG 1 -
4 Goods lift 1 -
5 Electrical & electrical installation - -
6 Incinerator plant 1 -
No Description Qty MOC Jacketed Lining Horizontal / vertical Ends, dished, conical, flat etc., Open or closed Agitator Gear box / motor Approx size Remarks
1 Napthalene Melter 1 MS Yes - Vertical Flat top & Conical Bottom closed - - 2 dia x 4 height -
2 Acid And Caustic Meter Ing tank 2 MS Vertical Flat top & Conical Bottom closed closed 1.25 dia x 2 ht
3 Sulphite feed tank 1 MS Vertical Flat top & Conical Bottom 2 dia x 2.5 ht
4 Sulphite storage tank 1 MS Vertical Flat top & Conical Bottom closed 2.5 dia x 4 ht
5 Vaccum traps 2 MS Vertical Dis ends closed 1 dia x 2 ht
6 Pressure filter 1 MS Vertical Dis ends closed 1 dia x 2 ht
7 Separator 1 MS Yes Vertical Flat top clonical bottom closed Yes Gear box and motors 2.5 dia x 4 ht
8 Crude BN storage tank 1 MS Yes Vertical Flat ends closed Yes Gear box 2 dia x 2.5 ht
9 Distillation colonm 1 SS Vertical Dis ends closed 0.7 dia x 5 ht
10 BN receiver 2 SS Yes Vertical Dis ends closed 1.4 dia x 2 ht
11 Catchall 1 SS Yes Vertical Dis ends closed 0.75 dia x 2.5 ht
12 BN waste water tank 1 MS Vertical Flat ends closed 1.5 dia x 2.5 ht
13 Hot water tank 1 MS Vertical Flat ends closed 1.5 dia x 2.35 ht
14 MS fusion pot 1 MS Limbate coil Vertical Flat ends closed 2 dia x 3 ht
15 Distillation vessel 1 SS Thermic fluiod Horizontal Dis ends closed 2 dia x 3 l
16 Flaker 1 SS Cooling inner Horizontal Dis ends closed Gear box Chain drive
17 CI sulphonator 1 CI Yes Vertical Dis ends closed Yes Gear box 2 dia x 2.5 ht
18 CI fusion pot 1 SS Insulated Vertical Flat ends closed Yes 2 dia x 5 ht
19 Napthalene stripes 1 MS - Tile lined Vertical Dis ends closed 2 dia x 2.5 ht
20 Neutralization vessel 1 MS - Tile lined Vertical Dis ends closed Yes Yes 2.5 dia x 3 ht
21 Acidification -essel 1 MS - Tile line Vertical d Vertical Dis ends closed Yes Yes 2.5 dia x 3.25 ht
22 Nutsche filter 2 MS Vertical Flat bottom open 2.9 dia x 2 ht
23 Blow case 1 MS Vertical Dis ends closed 2.5 dia x 3 ht
24 Crytilizer vessel 1 MS Yes Vertical Dis ends closed 2.5 dia x 2.5 ht
25 Condensor vent 1 SS closed 0.3 dia x 2.5 L
26 Condensor over head 1 SS Vertical closed 0.4 dia x 3 ht
27 Steam jet ejector 2 - Details not available
28 Filter press 1 PP Horizontal 3 ft x 3 ft 25 plates
29 Dryers model ASD 192 2 -
30 Napthalene condensor with coil 2 SS Yes Vertical 0.25 dia x 8 ht
31 Reflx receiver 1 SS Yes Vertical Flat top bottom closed 0.75 dia x 1.5 ht
32 Furnace oil stroage tank 2 MS Horizontal Dis ends closed 18 KL each Steam with coils
33 Auto clave 1 MS Horizontal Dis ends closed Yes Gear box 1.1 dia x 3.7 L
34 Condensor over head 1 MS Horizontal closed 0.75 dia x 3 L
35 BH wash water mtank with coils 1 MS Horizontal Dis ends closed 2.3 dio x 3.2 L
36 Steam ejecteor 1 - Details not available
37 Blow case 1 MS Damaged condition
38 Diesel fired baby boiler 1 - Vertical 60 kg per hr @ 15 kg/cm2 Aerotherm
39 Goods lift,rope,hoist 1 - 2 tons indef ele
40 Vaccum pump,water ring used, 2 - 440 cum, VAC 710 mm Mazda
41 Vaccum pump water ring new 2 - 440 cum, vac 710 mm Mazda
42 Steam boiler 1 - 3/1.5 T/H Veeson FO/wood
43 Incinerator plant 1 - Details not available
44 Cooling tower FRB 1 - Shell only available
45 Quench vessel 1 MS Semi jack Horizontal Dis ends closed Yes Gear box 3 dia x 3.5 L Chain drive
46 Hot oil unit 1 - 1 lac-k/cal/hr @ 250 D c
47 Hot oil unit 1 - 2 lac-k/cal/hr @ 3000 D c
48 Electrical MCC panel - -
49 Gear box and motors - -
Copyright © 2013 Nagoorar Enterprises Private Ltd.,
Powered by Big Network